You are bidding on an Lecroy / Teledyne DA1855A PR2 High Performance, 100 MHz Dual Channel Differential Amplifier. It will arrive with a fresh calibration with certificate performed by an ISO 17025 accredited lab! It has a list price of $14,000 USD!
The DA1855A is a stand-alone, high-performance 100 MHz differential amplifier. It is intended to act as a signal conditioning preamplifier for oscilloscopes, digitizers and spectrum analyzers, providing differential measurement capability to instruments having only a single-ended input. When used with a DA1855A, oscilloscopes can obtain Common Mode Rejection Ratio (CMRR) and overdrive recovery performance levels previously unobtainable.
Amplifier gain can be set to 1 or 10. A built-in input attenuator can be separately set to attenuate signals by a factor of 10, providing gains of 10, 1, or 0.1 and common mode dynamic range of ±15.5 V (÷1) or ±155 V (÷10). Optional probes increase the maximum input signal and common mode ranges in proportion to their attenuation ratio but do not exceed their maximum input voltage rating. Effective gain of the DA1855A, including probe attenuation, amplifier gain and attenuator settings, is automatically displayed.
The DA1855A has a bandwidth of 100 MHz, but any one of the three 3-pole bandwidth limit filters can be selected to reduce bandwidth to 20 MHz, 1 MHz or 100 kHz to limit noise above the frequency of interest.
The DA1855A output is carefully limited to ±500 mV, so that the oscilloscope is not overdriven by large inputs. This allows many oscilloscopes to directly measure the settling of D/A converters with 14-bit (60 ppm) precision, better than any other differential comparator.
The DA1855A features a built-in Precision Voltage Generator (PVG) that can be set to any voltage between ±15.5 V (±10 V in Differential Offset) with up to 100 µV resolution. The PVGs output can be selected as an input to the inverting (-) input of the amplifier for operation as a differential comparator or applied internally as a true differential offset voltage. The PVG is also available for external use through a rear panel connector.
The DA1855A operates from 90 to 250 VAC line without line switching. High-performance differential probes such as the DXC100 ÷10/÷100 high CMRR probes are recommended.
Overdrive Recovery
With a ÷100 probe, the DA1855A settles to within 100 mV referred to input, from a 400 V input signal within 100 ns. With attenuating probes, this allows the in circuit measurement of dynamic saturation in switch mode power converter switching devices.
Comparator Mode
The DA1855A becomes a differential comparator when the internal PVG output is selected as the amplifier's inverting (-) input. In this mode, the DA1855A can be used to very accurately measure relatively small signals that are riding on large AC or DC components. Due to the precision of the voltage generator, an oscilloscope, when used with the DA1855A, can make voltage measurements that are much more accurate than the oscilloscope is capable of by itself. The output of the PVG is available for external use via a rear panel connector.
True Differential Offset Mode
The DA1855A has built-in Precision Voltage Generator can be used to generate a true differential offset while still allowing both inputs to be used as differential inputs. The offset range can be as high as ±50,000 divisions and the generator has 5 1/2 digit resolution. This mode facilitates making measurements such as changes to a transistor's base to emitter voltage caused by variations in temperature and/or current. Used in this mode, the voltage generator can be set to a value that will zero out the static value of the junction's on voltage. The DA1855A's differential measurement capability will reject any dynamic signal common to both sides of the junction, and the oscilloscope is left to measure only the changes in the junction voltage.
Autobalance
Each time either gain setting button is pressed, the DA1855A automatically adjusts the amplifier's DC balance.
Features and Benefits
⦁ Full control from oscilloscope through ProBus interface
⦁ DC to 100 MHz bandwidth
⦁ Outstanding 100,000: 1 Common Mode Rejection Ratio (CMRR)
⦁ Gain of X1 or X10
⦁ Industry-leading overdrive recovery
⦁ Low noise
⦁ Selectable BW limiting
⦁ Two gain control modes when connected to a LeCroy oscilloscope
⦁ Built-in Precision Voltage Generator (PVG)
⦁ Comparator and true differential offset modes
This unit is in excellent condition, has been fully tested and is guaranteed functional. It comes w/ a 14 day right of return should it not perform to your expectations. Please review pics and text carefully before bidding to verify accuracy of description. If you don't see it in the pictures, it is not included.
Insurance is included in UPS shipping charges.
Item shipped internationally on buyer's UPS, FEDEX or DHL accounts only.We will accept payment for this item by company check, cashier’s check and wire transfer only.
Feel free to send any questions regarding this item to:
(in fact I encourage you to do so)
If you have zero feedback,
contact us prior to purchase so we know you are a serious bidder. Otherwise, we may cancel your bid before the auction closes. It should be obvious that you should only bid if you are serious and do intend to complete the transaction.
Any stated warranty will be voided if the unit is opened or if any calibration or lockout stickers have been tampered with or removed.
Please note that shipping and insurance costs are non-refundable.
Our feedback is very important to us and we strive for 100% positive on every transaction. If you are unsatisfied with any aspect of your transaction, please contact us before leaving negative or neutral feedback so that we can address and remedy the issue immediately. Additionally, we are always happy to leave positive feedback for our trading partners after a successful transaction.
Make sure that you check out