Keithley 224 1V to 105V / 5nA to 100mA Programmable Current Source - CALIBRATED!

$1,850.00
(No reviews yet) Write a Review
SKU:
253849942773
Condition:
Refurbished
Brand:
Keithley
MPN:
224
Model:
224
Keithley 224 1V to 105V / 5nA to 100mA Programmable Current Source - CALIBRATED!

Product Description

Seller refurbished

 

 
 
Shop Categories
 

We buy, sell and rent general purpose, optical and RF test and measurement equipment. We pay top dollar for your unwanted, surplus or defective gear. Let us make you an offer on your new or used Agilent, Tektronix, Anritsu, Fluke, Rohde & Schwarz and IFR instruments.

 

Keithley 224 1V to 105V / 5nA to 100mA Programmable Current Source - CALIBRATED!

 
Item Description

Keithley 224 1V to 105V / 5nA to 100mA Programmable Current Source - CALIBRATED!


You are bidding on a Keithley 224 1V to 105V / 5nA to 100mA Programmable Current Source. It will arrive with a fresh calibration performed by an ISO 17025 accredited lab. The Keithley 224 programmable current source was designed for general purpose bench or system use. The INCREMENT/DECREMENT function is manual or automatic, and selectable dwell times provide stepped ramp capabilities. The AUTO function allows automatic incrementing or decrementing of the output. Time per step can be set from 50ms/step to 999.9s/step. In some applications, it is necessary to limit the voltage across the device under test. The Model 224 offers compliance limit settings ranging from ±1V to ±105V in 1V steps. A blinking LED indicates V-LIMIT or bench operation.

Features:

Display: 0.5 in LED digits, 4½-digit signed mantissa, 1-digit signed exponent

Maximum Allowable Common Mode Voltage (Output or Output Common to Chassis): 250 V rms, DC to 60 Hz

Increment/Decrement: automatic, manual or trigger modes

Range of Dwell Times: 50 ms to 999.9 s

Output Load: Output load must be non-inductive

External Trigger: TTL-compatible External Trigger Input and Output

Output Connections: Teflon insulated 2-lug triax connector (specialty connector 30JR121-1) for output; five way binding posts for GUARD, OUTPUT COMMON and CHASSIS GROUND; BNC (chassis isolated) connectors for EXTERNAL TRIGGER INPUT and OUTPUT

All connections on rear panel

You can view the performance specifications here: Data Sheet

This unit is in excellent condition, has been fully tested and is guaranteed functional. It comes w/ a 14 day right of return should it not perform to your expectations. Please review pics and text carefully before bidding to verify accuracy of description. If you don't see it in the pictures, it is not included.

Insurance is included in UPS shipping charges. Item shipped internationally on buyer's UPS, FEDEX or DHL accounts only.

We will accept payment for this item by company check, cashier’s check and wire transfer only. 

Feel free to send any questions regarding this item to:

(in fact I encourage you to do so)

If you have zero feedback, contact us prior to purchase so we know you are a serious bidder. Otherwise, we may cancel your bid before the auction closes. It should be obvious that you should only bid if you are serious and do intend to complete the transaction. Any stated warranty will be voided if the unit is opened or if any calibration or lockout stickers have been tampered with or removed. 
 
Please note that shipping and insurance costs are non-refundable. 

Our feedback is very important to us and we strive for 100% positive on every transaction. If you are unsatisfied with any aspect of your transaction, please contact us before leaving negative or neutral feedback so that we can address and remedy the issue immediately. Additionally, we are always happy to leave positive feedback for our trading partners after a successful transaction. 

Make sure that you check out my other auctions for great deals on other test and measurement equipment.

 



Thank you and good luck bidding.




 photo test 80 2015 148_zps1lkkrjk2.jpg

 photo test 80 2015 149_zpspai0mkrz.jpg

 photo test 80 2015 152_zps4ps1zqxu.jpg

 photo test 80 2015 154_zpsmcgxzkfx.jpg

 photo test 80 2015 155_zpsjk4uo9tj.jpg

 photo test 80 2015 156_zps8fqwkcyb.jpg

 photo test 80 2015 158_zpstbrroff3.jpg
 

Need your unit calibrated by an ISO 17025 accredited lab prior to shipment? Not a problem. We work with numerous calibration and repair companies that can provide your required service at competitive prices.