You are bidding on an Anritsu MS4623C 10 MHz - 6 GHz Vector Network Analyzer with Options 01 (Rack Mount), 03 (Internal 2nd Source / 3rd Test Port / Test Attenuator), 11 (Default Connector - Type N(F)), 13 (Intermodulation Distortion Measurements) and 24 (Processing Upgrade). It will arrive with a fresh calibration performed by an ISO 17025 accredited lab.
The Anritsu MS4623C 6 GHz, 2-Port Vector Network Measurement System / Direct Receiver Access with direct access to the receivers (i.e. without an integrated test set). This vector network analyzer offers the ultimate flexibility for power amplifiers, frequency translating, and multiple output device requirements.
Specifications:
Frequency Range: 10 MHz to 6 GHz. Source Power Range (No Options): +7 to 85 dBm. Level Accuracy: ±1 dB. Sweep Range: 20 dB Minimum. Harmonics: 30 dBc. Stability: <5 ppm / year. Receiver Average Noise, 10 Hz: 115 dBm (<3 GHz), 105 dBm (3 to 6 GHz). Receiver 0.1 dB Compression: +7 dBm. Receiver Maximum Input: +27 dBm. Receiver Damage Level: +30 dBm. System Dynamic Range (Terminated): 125 dB (10 to 3000 MHz), 110 dB (3000 to 6000 MHz). High Level Noise: <0.008 dB rms (10 to 3000 MHz),<0.018 dB rms (3000 to 6000 MHz). IF Bandwidth Range: 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, and 30 kHz. Data Points: 1, 3, 15, 51, 101, 201, 401, 801, and 1601; Arbitrarily use Discrete Fill for 2 to 1601 points. Impedance: 50 Ohms. Frequency Resolution: 1 Hz. Power Output Range Source 1 (2-Ports No Options): +10 to 85 dBm (10 MHz to 3 GHz), +7 to 85 dBm (10 MHz to 6 GHz). Power Control Range: >20 dB. The minimum absolute level for power sweep is -15 dBm while the maximum power output for a unit is typically +10 dBm, depending upon configuration. Power Level Accuracy: ±1 dB to 6 GHz (no flat power calibration applied; full-band frequency sweep at -15 dBm, 0 dBm, and maximum rated power). Sweep Type: Linear, CW, Marker, or N-Discrete point sweep. Liquid Crystal Display: A Color 8.4" Thin Film Transistor (TFT) LCD display.
Installed Options:
1 Rack Mount
3 Internal 2nd Source / 3rd Test Port / Test Attenuator
11 Default Connector - Type N(F)
13 Intermodulation Distortion Measurements
24 Processing Upgrade: Adds processing upgrades for (1) additional data points (from 401 to 1601) when performing balanced/differential measurements on 3-port devices, (2) S4P file use in embedding/deembedding matching circuits, (3) additional throughput enhancements
You can view the specs for this unit here: MS4623C Specs