Agilent 83433A / 83434A 10Gb/s Lightwave Transmitter & Receiver - CALIBRATED!

$6,950.00
(No reviews yet) Write a Review
SKU:
253850275067
Condition:
Refurbished
Brand:
Agilent
Model:
83433A / 83434A
MPN:
83433A / 83434A
Agilent 83433A / 83434A 10Gb/s Lightwave Transmitter & Receiver - CALIBRATED!

Product Description

Seller refurbished

 

 
 
Shop Categories
 

We buy, sell and rent general purpose, optical and RF test and measurement equipment. We pay top dollar for your unwanted, surplus or defective gear. Let us make you an offer on your new or used Agilent, Tektronix, Anritsu, Fluke, Rohde & Schwarz and IFR instruments.

 

Agilent 83433A / 83434A 10Gb/s Lightwave Transmitter & Receiver - CALIBRATED!

 
Item Description

Agilent 83433A / 83434A 10Gb/s Lightwave Transmitter & Receiver - CALIBRATED!


You are bidding on an Agilent 83433A / 83434A (w/ Option 106 - Clock recovery at 10.66 GHz) 10Gb/s Lightwave Transmitter and Receiver Optical System. It will arrive with a fresh calibration performed by an ISO 17025 accredited lab. The Agilent 83433A transmitter and the Agilent 83434A receiver provide the optical interfaces necessary to allow bit error ratio testing of 10 Gb/s optical transmitters and receivers used in 10 Gb/s SONET/SDH, 10 GigE, and IP optical net-works as well as systems employing forward error correction (FEC). The 83433A and 83434A may be combined to create a complete optical link for system or fiber testing.

The Agilent 83433A lightwave transmitter is based on a lithium niobate modulator driven by an internal CW DFB 1552.52 nm laser. The laser and modulator are inter-connected externally with a PMF fiber. The modulator can also be used with an external laser with polarization maintaining fiber such as the Agilent 8164A, with 81680A option 071. The Agilent 83433A is designed to produce high fidelity, low jitter waveforms for 2.488 Gb/s STM-16/OC-48, 9.953 Gb/s STM-64/OC-192 and other transmission rates up through 10.7 Gb/s. The Agilent 83433A is intended for BER testing with error performance analyzers such as the Agilent 71612B. The Mach-Zehnder modulator is adjusted for a fixed zero chirp. Its output waveform produces a minimum extinction ratio of 12 dB. The internal DFB laser can be modulated at frequencies from 15 kHz to 10 MHz to increase linewidth for SBS suppression or channel identification applications. The internal laser wavelength can be adjusted ±1.25 nm around the 1552.52 center wavelength. The Agilent 83433A can be combined with the Agilent 83434A 10 Gb/s lightwave receiver to create a complete optical link for system or fiber testing, or to form a basis for substitution testing of commercial transmitters and receivers. Specifications. Digital Data Input; Data rate compatibility: 2.4 to 10.7 Gb/s. Amplitude: 0.5 to 1.5 V pk-pk. Return loss: 12 dB minimum (0.1 to 5000 MHz), 9 dB minimum (5000 to 10,700 MHz). Impedance: 50 ohm. Mark density: 45 to 55%. Maximum run of consecutive ones or zeros: 100 bits. Polarity: non-inverting. Maximum Safe Input Level; Digital data input: 2.0 V pk-pk; +2.0, 2.0 V dc. Low-frequency modulation input: 2.0 V pk-pk. External optical modulator input: +14 dBm. Low-Frequency Modulation Input; Frequency range 3 dB points: 0.015 to 10 MHz. Amplitude for 5% mod index: 0.5 to 1.5 V pk-pk; 1 V pk-pk nominal. Internal Laser Output; CW power: +8.5 to +11.5 dBm; +10 dBm nominal. Wavelength: 1552.42 to 1552.62 nm; 1552.52 nominal. Wavelength adjustment range: 1 to +1 nm. Spectral width at 20 dBc (Full Width Half Maximum): 10 MHz maximum. Side-mode suppression ratio: 30 dB minimum. Optical Modulator Input; Wavelength: 1530 to 1565 nm. Optical power input: +2 to +12 dBm. Input return loss: 27 dB minimum.

The Agilent 83434A 10 Gb/s lightwave receiver is designed to recover clock data and to provide linear, non-retimed data from digitally modulated SDH/ SONET STM-64/OC-192 optical signals, as well as signals employing forward error correction (FEC) at 10.664 Gb/s (option 106). The receiver is based on an amplified PIN receiver to produce a linear output with AGC stabilization. The receiver is designed to provide 16 dBm sensitivity with PRBS lengths to 231 –1 with BER performance of at least 1E-10. The recovered clock can be used as a trigger input for the Agilent Infiniium DCA to allow optical eye diagram measurements when no external clock signal is available for triggering. The recovered clock also provides the required clock input for the error detector of the Agilent 71612B error performance analyzer. The non-retimed data output can be used with an error detector to measure and optimize BER. The output of the receiver is also appropriate for eye contour and Q-factor measurements. The Agilent 83434A can be combined with the Agilent 83433A 10 Gb/s lightwave transmitter to create a complete optical link for system or fiber testing, or to form a basis for substitution testing of commercial transmitters and receivers. Specifications. Optical Input; Wavelength: 1300 to 1600 nm. Optical input power: 16 to 0 dBm. Return loss: 28 dB minimum. Loss of optical input” alarm threshold: 25 to 20 dBm. Maximum Safe Input Level; Optical input power: +7 dBm maximum. Data Output; Amplitude: 0.5 to 1.5 V pk-pk. Lower 3 dB frequency: 0.10 MHz. Upper 3 dB frequency: 6.5 GHz. Return loss: 9.5 dB minimum. Impedance: 50 ohm. Recovered Clock Output; Amplitude: 0.5 to 1. 5 V pk-pk. Frequency: 9953.26 to 9953.30 MHz; 9953.28 nominal. Frequency (opt. 106): 10664.03 to 10664.43 MHz; 10664.23 nominal. Duty cycle: 45/55% maximum; 50/50% nominal. Clock to data alignment: ±25.12 ps maximum. 3 dB bandwidth: 8 to 12 MHz; 10 MHz nominal. Jitter generation: 2 ps rms maximum. Return loss: 12 dB minimum. Impedance: 50 ohm. Option 106 For FEC signals, substitutes clock recovery at 10.644 GHz.

You can view the specs for this system here: Data Sheet

This unit is in excellent condition, has been fully tested and is guaranteed functional. It comes w/ a 14 day right of return should it not perform to your expectations. Please review pics and text carefully before bidding to verify accuracy of description. If you don't see it in the pictures, it is not included.

Insurance is included in UPS shipping charges. Item shipped internationally on buyer's UPS, FEDEX or DHL accounts only.

We will accept payment for this item by company check, cashier’s check and wire transfer only. 

Feel free to send any questions regarding this item to:

(in fact I encourage you to do so)

If you have zero feedback, contact us prior to purchase so we know you are a serious bidder. Otherwise, we may cancel your bid before the auction closes. It should be obvious that you should only bid if you are serious and do intend to complete the transaction. Any stated warranty will be voided if the unit is opened or if any calibration or lockout stickers have been tampered with or removed. 
 
Please note that shipping and insurance costs are non-refundable. 

Our feedback is very important to us and we strive for 100% positive on every transaction. If you are unsatisfied with any aspect of your transaction, please contact us before leaving negative or neutral feedback so that we can address and remedy the issue immediately. Additionally, we are always happy to leave positive feedback for our trading partners after a successful transaction. 

Make sure that you check out my other auctions for great deals on other test and measurement equipment.

 



Thank you and good luck bidding.




 photo P1070268_zpsaops7q6z.jpg

 photo P1070266_zpsm8ivg8o4.jpg

 photo P1070273_zpsjlildauj.jpg

 photo P1070271_zpsbe9jfl52.jpg

 photo P1070275_zps4cbswc4w.jpg

 photo P1070277_zps1ncjrhc2.jpg

 photo P1070278_zpsgqbbptkq.jpg

 photo P1070285_zpsxendusir.jpg

 photo P1070279_zpsehozaf8j.jpg

 photo P1070282_zpsdniqyb2b.jpg

 photo P1070286_zpscy5utgfm.jpg

 photo P1070287_zps4wv4eryd.jpg

 photo P1070284_zpsblnl4lgw.jpg

 photo P1070283_zpsigiy6p5f.jpg

 

Need your unit calibrated by an ISO 17025 accredited lab prior to shipment? Not a problem. We work with numerous calibration and repair companies that can provide your required service at competitive prices.